Siemens 5SY7310-6 — 3-Pole MCB (DIN Rail)

Siemens 5SY7310-6 SENTRON MCB, 3P, 10A, B Curve, 15/30 kA

MPN5SY7310-6
Active

Siemens SENTRON 5SY7 series, 3-pole miniature circuit breaker, 10 A, B tripping characteristic, 15 kA per EN 60898 / 30 kA per IEC 60947-2, 3 MW units, IP20 with conductors.

$34.29Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7310-6 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY7310-6 — Protection
ParameterValue
Tripping characteristic (curve)B
Breaking capacity per EN 6089815 kA
Breaking capacity per IEC 60947-230 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree3
5SY7310-6 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)1.3 W
Neutral conductor switchingNo
Rated voltage (AC, single-phase)440 V
5SY7310-6 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
Accepts supplementary devicesYes
5SY7310-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
Vibration resistance (IEC 60068-2-6)±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz

Product details

Siemens 5SY7310-6 — SENTRON 3-pole MCB, 10 A, B curve

At 40 °C the continuous rating derates to 9.52 A, at 50 °C to 9.02 A, and at 60 °C to 8.48 A; if the panel ambient runs hot, size up one amp rating to hold the load. The 30 kA IEC 60947-2 rating gives headroom for high-fault installations (industrial mains with transformer impedances below 5%), while the 15 kA EN 60898 rating satisfies residential and light commercial coordination.

Current production. No successor issued.

Panel integration

Sealable terminals let the commissioning engineer lock the cover screws after inspection — useful for utility or metering compartments where tamper evidence is required.

Certified to IEC / EN 60898-1, IEC / EN 60947-2, and UL1077, covering the three main approval regimes for miniature breakers in Europe and North America. Halogen-free and silicon-free construction avoids outgassing issues in sealed enclosures or near sensitive contacts. The energy limitation class 3 rating means it limits let-through energy during a fault — relevant for downstream component protection in a coordinated panel.

Frequently asked questions

What compliance documentation does Siemens provide for the 5SY7310-6?

The breaker carries certifications to IEC / EN 60898-1, IEC / EN 60947-2, and UL1077. It is halogen-free and silicon-free. Documentation typically includes the declaration of conformity and the datasheet with the full derating curve.

MPN
5SY7310-6