Skip to main content
Siemens 5SY7506-7 — 1-Pole MCB (DIN Rail)

Siemens 5SY7506-7 SENTRON MCB, C-Curve 2-Pole 1P+N, 15/40 kA

MPN5SY7506-7
Active

Siemens SENTRON 5SY7506-7 miniature circuit breaker, C characteristic, 2-pole (1P+N), 230 V AC, 15 kA (EN 60898) / 40 kA (IEC 60947-2), 36 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY7506-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry
5SY7506-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SY7506-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY7506-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SY7506-7 — SENTRON MCB, C-Curve, 2-Pole

It carries a 15 kA breaking capacity per EN 60898 and 40 kA per IEC 60947-2, so it handles high prospective fault currents common in industrial panel feeds — the 40 kA figure is the one that matters for SCCR coordination downstream of a transformer or large motor branch. Rated for 230 V AC (single-phase) and up to 60 V DC, with neutral conductor switching built in.

Any mounting position, IP20 with conductors connected. Sealable, halogen-free, silicon-free. Combined terminals top and bottom, supply cord position any — no orientation restrictions inside the panel.

Current production — no phase-out or last-time-buy announced.

Frequently asked questions

What are the key breaking capacity ratings for 5SY7506-7?

15 kA per EN 60898 at 230 V AC, 40 kA per IEC 60947-2 at 230 V AC, and 15 kA at DC per IEC 60947-2. For UL 1077 / CSA C22.2 No.235 applications the rating is 5 kA.

What compliance documentation does this brand provide for 5SY7506-7?

The breaker is certified to IEC / EN 60898-1, IEC / EN 60947-2, and UL 1077. It is halogen-free and silicon-free. Specific RoHS/REACH declarations are available from the manufacturer.

Will 5SY7506-7 drop into a panel that was specified around 5SY4140-7 without rewiring?

Both are 2-pole 1P+N SENTRON MCBs with the same 36 mm width and DIN-rail mounting, so physical fit is the same. The 5SY7506-7 carries higher breaking capacity (40 kA vs the 5SY4140-7's typical 10 kA), so it can replace it directly as long as the C-curve and voltage ratings match the branch circuit.

How do I get current pricing and availability for 5SY7506-7?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time.

MPN
5SY7506-7