ABB 1SFA896106R1100 PSR12 Softstarter, 208-600 V AC

MPN 1SFA896106R1100
Active

ABB, PSR12 series, softstarter, order code 1SFA896106R1100, 208... 600 V AC, 24 V AC/DC control supply, 0... 20 second ramp time.

$274.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

1SFA896106R1100 specifications
ParameterValue
Terminal typeScrew Terminal
Voltage208 ... 600 V AC
Frequency50/60 Hz
ProtocolFiledBusPlug(Optional)
Temp operating max60 °C
Temp operating min-25 °C

Product details

Functional envelope

The ABB 1SFA896106R1100 is a PSR12 softstarter with voltage ramp start, 0... 20 second ramp time, and adjustable initial voltage during start of 40... 70 % with a step-down special ramp of 100... 60 %. Starting capacity is rated 4xIe for 6s, so it handles the inrush profile of a standard induction motor within the PSR frame class. Control supply is 24 V AC/DC, and the device runs on 208... 600 V AC at 50/60 Hz, covering common industrial mains from a single unit.

Overload coordination and signaling

Electronic overload is not integrated and the unit has no current limit function, so protection is specified separately: the data sheet recommends an ABB MS132 10.00... 16.00 overload. Wire that breaker upstream and coordinate its trip class with the softstarter's 4xIe for 6s starting capacity. A run signal relay is present; fault, by-pass, and overload signal relays are not. If the panel logic expects a fault contact, plan to source that from the upstream MS132 rather than from the softstarter itself.

Fieldbus and wiring

Communication is via an optional FieldBusPlug; the base unit ships without a fieldbus interface. Terminals are screw type, main circuit rigid 1/2 x 0.75... 2.5 mm², control circuit 1 x 0.75... 2.5 mm², control-circuit tightening torque 1 N·m. Main terminals IP20.

Environment and compliance

Operation is rated -25... +60 °C ambient, service factor 100 %. The unit is RoHS compliant following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019, WEEE category 5 small equipment, B2B.

MPN
1SFA896106R1100