Skip to main content
Schneider Electric A9C20432

Schneider Electric A9C20432 Acti9 iCT Contactor, 2P, 25 A, 1

MPN A9C20432
Obsolete

Schneider Electric Acti9 iCT contactor, A9C20432, 2P, 25 A AC-7A, 127 V AC 60 Hz coil, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9C20432 key specifications
ParameterValue
Control typeRemote control
Control signal typeMaintained
Main product or component typeContactor
Voltage250 V AC 60 Hz
Coil voltage127 V AC 60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Current25 A AC-7 A 8.5 A AC-7B
Frequency100 switching operations/day
Poles2P
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C

All specifications

A9C20432 additional specifications
ParameterValue
Temp operating min-5 °C
Storage temperature-40...70 °C
Pollution degree2
ColorWhite
Depth68.5 mm
Width18 mm
Height81 mm
Mechanical life cycles1000000 cycles
ApplicationMotor-heating-lighting
Operating temperature-5...60 °C

Product details

The control coil is rated 127 V AC at 60 Hz, drawing 15 VA inrush and 1.3 W holding at 250 V AC. That maintained control signal means the coil stays energized to keep the contacts closed — plan for continuous power draw on the control circuit. Rated operational current is 25 A in AC-7A duty (resistive/motor loads) and 8.5 A in AC-7B (heating/lighting), at 250 V AC 60 Hz.

At 18 mm wide (1 module width on a DIN rail), this contactor fits tight enclosures — two units occupy 36 mm, or 9 mm pitch positions. The IP20 finger-safe body is fine for enclosed panels; the optional IP40 modular enclosure rating adds splash protection for semi-exposed mounting. Electrical durability is rated at 100,000 cycles at 25 A AC-7A, and 30,000 cycles at 8.5 A AC-7B or under AC-3 motor-switching duty. Mechanical durability is 1,000,000 cycles. For a lighting or small-motor contactor in a commercial building, that's a decade-plus of daily switching at 100 operations per day. Terminals are tunnel-type: power circuit accepts 1.5 to 6 mm² rigid or 1 to 4 mm² flexible; control circuit accepts 1.5 to 2.5 mm². Tightening torque is 0.8 N·m for both circuits — consistent with standard DIN-rail terminal blocks, so no special tooling needed.

MPN
A9C20432