Skip to main content
Schneider Electric A9C24732

Schneider Electric A9C24732 Acti9 iCT Contactor, 2P, 25 A AC

MPN A9C24732
Obsolete

Schneider Electric Acti9 iCT, contactor, A9C24732, 2P, 25 A AC-7a, 230-240 V AC 50 Hz coil, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9C24732 key specifications
ParameterValue
Control typeRemote control
Control signal typeMaintained
Main product or component typeContactor
Voltage250 V AC 50 Hz
Coil voltage230...240 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
Current25 A AC-7 A 8.5 A AC-7B
Frequency100 switching operations/day
Poles2P
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C

All specifications

A9C24732 additional specifications
ParameterValue
Temp operating min-5 °C
Storage temperature-40...70 °C
Pollution degree2
ColorWhite
Depth68.5 mm
Width18 mm
Height81 mm
Mechanical life cycles1000000 cycles
ApplicationMotor-heating-lighting
Operating temperature-5...60 °C

Product details

It carries a 25 A rated operational current in AC-7a duty (IEC/EN 61095) and a 230-240 V AC 50 Hz control coil. The 2 NO pole contact composition means it switches two line conductors simultaneously — typical for single-phase motor or resistive heater circuits where both poles need breaking.

The 25 A AC-7a rating is the headline figure — AC-7a covers motor loads with moderate inrush (fans, pumps, compressors up to that running current). The same contactor is also rated 8.5 A in AC-7b (heavily inductive loads like solenoid valves) and carries AC-3 and AC-5a/b ratings per EN/IEC 60947-4-1 for motor switching and lamp/transformer loads. Electrical durability varies by duty: 100,000 cycles at 25 A AC-7a, 30,000 cycles at 8.5 A AC-7b. Mechanical durability is 1,000,000 cycles — the contactor will outlast the electrical life in most applications. The control coil draws 9.2 VA inrush and holds at 2.7 VA — a standard AC coil draw that a PLC digital output with an interposing relay can drive. The 230-240 V AC 50 Hz coil voltage is fixed; no dual-voltage or DC coil option on this variant. Tightening torque is 0.8 N.m for both control and power circuits, with tunnel-type terminals accepting up to 6 mm² rigid or 4 mm² flexible on the power side.

MPN
A9C24732