Schneider Electric A9CR4263

Schneider Electric A9CR4263 Acti9 REDs RCCB, 63 A, 30 mA, Ty

MPN A9CR4263
Active

Schneider Electric Acti9 REDs A9CR4263, 2P RCCB recloser, 63 A rated current, 30 mA earth-leakage sensitivity Type A, 230 V AC, 50 Hz, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9CR4263 specifications
ParameterValue
Control typeToggle
Protection typeRecloser
Voltage230 V AC 50 Hz phase to neutral
Insulation voltage ui500 V
IP ratingIP20
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-5 °C
Storage temperature-40...70 °C
ColorGrey
Depth82 mm
Width54 mm
Height106 mm
Mechanical life cycles4000 cycles open-close
Operating temperature-5...40 °C

Product details

The Schneider Electric A9CR4263 is an Acti9 REDs residual current circuit breaker (RCCB) with integrated recloser — a 2-pole device rated 63 A at 230 V AC, 50 Hz, with 30 mA earth-leakage sensitivity Type A. Type A earth-leakage protection means it detects both sinusoidal AC residual currents and pulsating DC residual currents — the standard for circuits supplying single-phase electronics, switched-mode power supplies, and appliances with rectifiers. The 30 mA sensitivity covers personnel protection (direct contact) per IEC/EN 61008. The recloser logic is what sets this apart from a standard RCCB: after a fault trip, it waits 10 s, then attempts up to 3 reclose cycles with a 180 s minimum interval between closings. If the insulation fault persists, it stops the restart cycle and signals the fault. If the fault was transient (e.g., lightning surge or temporary leakage), the supply restores automatically — saving a site visit to reset a tripped breaker.

IP20 rated — suitable for dry indoor enclosures only. The toggle control and manual test function (operates above 100 V) let the commissioning engineer verify the trip mechanism without a dedicated test set.

Compliance documentation covers EN 50557 (requirements for automatic reclosing devices for RCCBs).

Key ratings in context

Mechanical durability is 4000 cycles open-close, which for a recloser in a distribution board translates to years of service under normal fault-clearing duty. The insulation fault diagnosis checks every 2 minutes if a fault is detected; the minimum leakage resistance threshold is 16 kΩ when operating and 8 kΩ when non-operating. The device also withstands 8/20 µs surge currents up to 250 A for electromagnetic compatibility.