Skip to main content
Schneider Electric A9F04401

Schneider Electric A9F04401 Acti9 iC60N MCB, 1 A C-Curve 4P

MPN A9F04401
Active

Schneider Electric Acti9 iC60N, A9F04401, miniature circuit breaker, 4P, 1 A, C-curve, 50 kA Icu at 380-415 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F04401 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F04401 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F04401 is an Acti9 iC60N miniature circuit breaker rated 1 A with a C-curve magnetic trip characteristic (8 x In ±20 %), 4 poles, and a 50 kA Icu breaking capacity at 380-415 V AC 50/60 Hz per EN/IEC 60947-2. The 4-pole version (4P) switches all four conductors — three phases plus neutral — and is typically used in three-phase distribution where the neutral must be switched for isolation or to meet local wiring rules.

Standards, approvals, and isolation capability

This MCB is dual-certified to EN/IEC 60898-1 (the household / similar installation standard) and EN/IEC 60947-2 (the industrial standard). That dual rating matters for a BOM line: it satisfies both the wiring-rule requirement (60898-1) and the industrial panel SCCR requirement (60947-2). The part is also suitability-for-isolation marked per both standards, meaning you can safely use it as a disconnecting means for the downstream circuit — the contact position indicator gives visual confirmation the contacts are open.

Mounting and integration into a DIN-rail enclosure

The 72 mm width occupies 8 x 9 mm pitches — a standard 4-pole MCB footprint. Depth is 78.5 mm, height 91 mm. Terminals accept 1-25 mm² rigid or 1-16 mm² flexible conductors, with a wire-stripping length of 14 mm and a tightening torque of 2 N.m. The double-terminal design (top and bottom) allows daisy-chaining or looping the supply without extra terminal blocks. IP20 finger-safe protection is standard for enclosed panel mounting.

MPN
A9F04401