Skip to main content
Schneider Electric A9F05325

Schneider Electric A9F05325 Acti9 iC60N MCB, D Curve, 25 A,

MPN A9F05325
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, 25 A, D curve, 3-pole, 36 kA breaking capacity, dual-standard EN/IEC 60947-2 & 60898-1, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05325 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F05325 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F05325 is an Acti9 iC60N miniature circuit breaker — a 25 A, D-curve, 3-pole unit rated for both AC and DC networks. Its 36 kA Icu at 12–133 V AC and 20 kA at 220–240 V AC mean it handles high prospective fault currents on distribution boards without needing an upstream current-limiting fuse.

Dual-standard rating and what it means for your panel

This breaker carries both EN/IEC 60898-1 (the MCB standard for household and similar installations) and EN/IEC 60947-2 (the industrial standard for circuit breakers). The 60898-1 rating gives you the 6 kA Icn at 400 V AC — the standard domestic/small-commercial fault level. The 60947-2 rating goes higher: 10 kA Icu at 380–415 V AC and 36 kA at low voltage.

DIN-rail footprint and panel integration

Snaps onto standard DIN rail — 6 x 9 mm pitches wide (54 mm), 91 mm tall, 78.5 mm deep. That 78.5 mm depth is shallow enough to clear most standard gland plates and enclosure backwalls. The toggle and trip indicator are front-facing; you can read the tripped state through the enclosure window without opening the door.

MPN
A9F05325