A9F05416 Acti9 iC60N 16A D Curve 4P MCB, 36 kA Breaking Capa

MPN A9F05416
Active

Schneider Electric Acti9 iC60N, A9F05416, miniature circuit-breaker, 4P, 16 A, D curve, 36 kA Icu at 12-133 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05416 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9F05416 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F05416 is a Schneider Electric Acti9 iC60N miniature circuit-breaker, 4 poles, rated 16 A with a D curve. It's built for distribution panels where high inrush loads—motors, transformers, welding gear—need a magnetic trip threshold of 12 x In ±20 % so the breaker doesn't nuisance-trip on startup. Breaking capacity hits 36 kA Icu at 12–133 V AC (EN/IEC 60947-2) and 10 kA Icn at 400 V AC (EN/IEC 60898-1), giving solid fault-clearing headroom for most industrial and commercial mains.

The D curve (12 x In magnetic trip) is the key differentiator here—it's sized for loads that draw a brief, high surge on energization, like a 16 A motor or a bank of switched-mode supplies. The 16 A rating is the continuous thermal current (In), so the load should not exceed 16 A steady-state. Breaking capacity of 36 kA Icu at low voltage (12–133 V AC) and 10 kA Icn at 400 V AC means this breaker can safely interrupt a short-circuit fault up to those levels without welding contacts or cascading upstream—critical for selectivity studies in a distribution board. Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (residential/commercial), so it's accepted in both worlds—panel builders often spec the 60947-2 rating for SCCR compliance, while the 60898-1 rating covers standard branch-circuit protection.

IP20 finger-safe front, but the busbar area is live when installed; isolate upstream before working on it. Trip indicator and contact-position indicator give visual confirmation of state without removing the cover.

MPN
A9F05416