Skip to main content
Schneider Electric A9F06120

A9F06120 Acti9 iC60H MCB, 20 A, 1P, B-Curve, 78.5 mm

MPN A9F06120
Active

Schneider Electric Acti9 iC60H, A9F06120, miniature circuit breaker, 1P, 20 A, B-curve, 42 kA Icu, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F06120 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F06120 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F06120 is a 1-pole Acti9 iC60H miniature circuit breaker rated 20 A with a B-curve trip characteristic. The 42 kA Icu at 12…60 V AC (EN/IEC 60947-2) gives you serious fault-clearing headroom on a 20 A branch; the 10 kA Icn at 230 V (EN/IEC 60898-1) is the domestic/commercial rating for that same breaker. Dual-standard certification means it qualifies for both industrial (60947-2) and residential (60898-1) applications, which simplifies BOM consolidation across panel builds. The thermal-magnetic trip unit combines a bimetal for overload protection and a solenoid for short-circuit.

Integration notes

The toggle actuator provides local on/off and a trip-indicator flag for quick fault isolation on the panel face. Depth of 78.5 mm and height of 91 mm mean it clears most standard enclosure gland plates and busbar shrouds.

MPN