Schneider Electric A9F68110

Schneider Electric A9F68110 Acti9 iT60 MCB, 10 A C-Curve, 1P

MPN A9F68110
Active

Schneider Electric Acti9 iT60N, miniature circuit breaker, 1P, 10 A, C-curve, 10 kA Icu at 230 V AC, 18 mm, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F68110 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Width18 mm
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F68110 is an Acti9 iT60N miniature circuit breaker — 1-pole, 10 A rated current, C-curve thermal-magnetic trip. It breaks 10 kA Icu at 220…240 V AC (EN/IEC 60947-2) and 6000 A Icn at 230 V AC (EN/IEC 60898-1). The 18 mm width snaps onto a DIN rail, leaving two 9 mm pitches occupied in the enclosure.

The C-curve magnetic trip triggers at 8 x In ±20 % — that is 80 A instantaneous, ±16 A. That suits it for mixed resistive-inductive loads where inrush is moderate (lighting banks, small motor circuits, control transformers).

Mounts on a DIN rail (EN/IEC 60715). Terminal accepts 1…25 mm² rigid or 1…16 mm² flexible copper — strip 14 mm, torque to 2 N·m. The removable comb busbar profile is compatible with the Acti9 range for daisy-chaining phases across multiple poles. IP20 B finger-safe terminals; no additional touch protection needed inside a closed panel. Ambient storage range -40…85 °C covers most site conditions; operating altitude 0…2000 m without derating.