Skip to main content
Schneider Electric A9L65401

Schneider Electric A9L65401 Acti9 iPRD65r Type 2 Surge Arres

MPN A9L65401
Active

Schneider Electric Acti9 iPRD65r, Type 2 surge arrester, 4P, 350 V, 65 kA max discharge, with remote signalling, clip-on DIN rail mount.

$188.05 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9L65401 specifications
ParameterValue
Voltage230/400 V AC (+/- 10 %) at 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Storage temperature-40...85 °C
ColorWhite (RAL 9003)
Depth69 mm
Width72 mm
Height85 mm
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9L65401 is an Acti9 iPRD65r Type 2 surge arrester — a 4-pole (4P) MOV-based protector for TN-C-S earthing systems in electrical distribution networks. It clips onto a DIN rail and is rated for a 230/400 V AC (+/- 10 %) 50/60 Hz network. The 65 kA common-mode maximum discharge current (L/PE and N/PE) and 20 kA nominal discharge current define its energy-handling capacity for induced lightning surges and switching transients. The 350 V maximum continuous operating voltage (Uc) matches the phase-to-earth voltage in a 230/400 V system.

Type 2 (Class II) per EN 61643-11:2012 / IEC 61643-11:2011 means it is designed for fixed installation at the sub-distribution board — it handles induced surges, not direct lightning strikes (that is Type 1). The 20 kA nominal discharge current (In) is the rating that governs its service life under repeated surges; the 65 kA maximum (Imax) is the single-event survival limit. The 337 V temporary overvoltage (Ut) withstand for 5 seconds between L/N means it can ride through a brief voltage swell without failing short — important for networks with unstable supply. The N/PE safe failure mode at 1200 V for 200 ms ensures the arrester fails open rather than creating a phase-to-earth fault.

Tunnel-type terminals on both top and bottom accept 2.5 to 35 mm² conductors; tighten to 2.5 N·m. The remote signalling contact (1 C/O, rated 0.25 A / 250 V AC) lets a PLC or annunciator monitor arrester status without opening the panel.

MPN
A9L65401