Schneider Electric A9N18548

A9N18548 Acti9 Vigi C120 4P 125A RCD, 300mA selective

MPN A9N18548
Active

Schneider Electric Acti9 Vigi C120, add-on residual current device, 4P, 125 A, Type AC, selective 300 mA, 230…415 V AC, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N18548 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230...415 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-1
IP ratingIP20
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width198 mm
Height95 mm
Mechanical life cycles20000 cycles
Operating temperature-5...60 °C

Product details

The A9N18548 is an add-on residual current device (RCD) from the Acti9 Vigi C120 range, designed to bolt onto the outgoing side of a compatible Acti9 MCB via screw terminals. At 125 A rated current and 300 mA selective earth-leakage sensitivity, it sits at the high end of the Vigi C120 family — sized for a main incomer or a large subfeed in a 230…415 V AC 50/60 Hz network. The selective time delay means it coordinates with downstream RCDs: it holds during a fault long enough for the closer device to clear, so only the faulted branch trips. That selectivity is critical in a distribution board feeding multiple sub-circuits where nuisance tripping of the main switch would take the whole panel down. The 4P (four-pole) construction switches all live conductors — three phases plus neutral — which is required for a three-phase outgoing group where the neutral must be disconnected and reclosed with the phases. Voltage-independent tripping technology means the RCD operates without needing an external power supply; the fault energy itself drives the mechanism, so protection holds even if the neutral is lost upstream. The 198 mm width (10 x 9 mm pitches) occupies ten modular spaces — plan the DIN-rail layout accordingly.

The device is certified to EN 61009 and IEC/EN 61009-2-1, the harmonised standard for residual-current-operated circuit-breakers with integral overcurrent protection (RCBOs) — though this is an add-on RCD, not a combined unit.

MPN