A9N18559 Acti9 Vigi C120 3P 125A 1000mA RCD Add-on Block

MPN A9N18559
Obsolete

Schneider Electric Acti9 Vigi C120 add-on residual current device, A9N18559, 3P, 125 A rated current, 1000 mA earth-leakage sensitivity, Type A-SI (Super Immunised), selective time delay, voltage independent tripping, clip-on 35 mm DIN rail mount, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N18559 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230...415 V AC 50 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-1
IP ratingIP20
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width171 mm
Height95 mm
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The A9N18559 is an add-on residual current device (RCD) from the Schneider Electric Acti9 Vigi C120 range. It is a 3-pole (3P) block rated at 125 A, designed to clip onto a compatible MCB (miniature circuit breaker) via screws, providing earth-leakage protection for outgoing circuits in a distribution board. Its 1000 mA sensitivity and Type A-SI (Super Immunised) classification mean it handles high-leakage industrial loads and is immune to nuisance tripping from transient surges or DC components — a common requirement on variable-speed drive or UPS-fed circuits.

Rated at 125 A continuous and 230...415 V AC 50 Hz, this block sits at the incomer or large subfeed position — think main switchboard feeders or high-current distribution. The 1000 mA earth-leakage threshold is deliberately high; it's not for personnel protection (that needs 30 mA) but for equipment and fire protection on circuits where normal leakage from filters and drives already runs tens of milliamps. Selective time delay (marked S) means it coordinates with downstream 30 mA RCDs — the downstream trips first, the upstream block holds off, keeping the rest of the board live. Voltage-independent tripping means it will clear a fault even if the neutral is lost — a safety net for IT or corner-grounded delta systems. Mechanical durability is rated at 20000 cycles — that's a maintenance interval, not a design life for frequent switching. This is a protective device, not a daily disconnect switch.

Clip-on mounting onto a 35 mm symmetrical DIN rail, occupying 10 pitches of 9 mm (171 mm width). Tunnel terminals accept 1...50 mm² rigid or 1...35 mm² flexible cable, with stripping length of 15 mm and tightening torque of 3.5 N.m.

Designed to EN 61009 and IEC/EN 61009-2-1, with pollution degree 3 per IEC 60947-2 and a rated impulse withstand voltage of 6 kV.