Skip to main content
Schneider Electric A9N18560

Schneider Electric A9N18560 Acti9 Vigi C120 RCD, 4P 125A 300

MPN A9N18560
Active

Schneider Electric Acti9 Vigi C120 add-on residual current device, 4P, 125 A, 300 mA, Type A-SI, selective, 230…415 VAC, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N18560 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230...415 V AC 50 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-1
IP ratingIP20
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width198 mm
Height95 mm
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The A9N18560 is an add-on residual current device (RCD) from the Schneider Electric Acti9 Vigi C120 range, designed to clip onto the outgoing side of a compatible MCB or MCCB to provide earth-leakage protection. It is rated for 125 A continuous current with a 300 mA Type A-SI (Super Immunised) sensitivity and a selective (time-delayed) trip characteristic, making it suitable for downstream coordination in distribution boards where nuisance tripping from transient leakage must be avoided.

The 125 A rated current sets the maximum continuous load this RCD can carry — sized for a main incomer or large subfeed in a commercial or industrial panel. The 300 mA sensitivity is above the 30 mA required for personal shock protection; this unit is intended for fire protection and equipment protection, not direct personnel protection. The Type A-SI classification means it detects sinusoidal AC and pulsating DC residual currents, and the 'Super Immunised' suffix indicates a higher immunity to high-frequency leakage from VFDs or UPS systems — a common source of nuisance trips in modern panels. The selective time delay allows coordination with downstream 30 mA RCDs, so only the faulted branch trips first.

The 4P (4-pole) form factor occupies 10 x 9 mm pitches, so 90 mm of DIN rail width. Tunnel-type terminals accept 1…35 mm² flexible or 1…50 mm² rigid cable; strip length 15 mm, tighten to 3.5 N·m. IP20 finger-safe for enclosed panel use only.

MPN
A9N18560