Skip to main content
Schneider Electric A9N1P25BIN

Schneider Electric A9N1P25BIN Acti9 xC60 MCB, 25 A, 1P, B-Cu

MPN A9N1P25BIN
Active

Schneider Electric Acti9 xC60 miniature circuit-breaker, A9N1P25BIN, 25 A rated, 1-pole, B-curve, 10 kA Icu at 240 V AC, clip-on 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N1P25BIN key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz 12...48 V DC 60 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to IS/IEC 60947-2
Breaking capacity10 kA Icu at 220...240 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 12...48 V DC conforming to IS/IEC 60947-2 6 kA Icu at 60 V DC conforming to IS/IEC 60947-2
Utilization categoryCategory A conforming to IS/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

A9N1P25BIN additional specifications
ParameterValue
Temp operating min-30 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth77.5 mm
Width18 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N1P25BIN is a 25 A rated, 1-pole miniature circuit-breaker from the Acti9 xC60 range, built to IS/IEC 60947-2. The 25 A [In] rated current sets the continuous load it can carry without tripping — sized for branch circuits feeding lighting, socket outlets, or small motor loads up to that ampacity. Breaking capacity is 10 kA Icu at 220...240 V AC 50/60 Hz, which means the breaker can safely interrupt a fault current up to 10,000 A at that voltage without welding its contacts or failing catastrophically. At 12...48 V DC it rises to 15 kA Icu, and at 60 V DC it drops to 6 kA Icu — important if this breaker is used in a DC control circuit or battery-backed bus. That 18 mm per pole is the standard modular width for a 1P MCB, so it fits existing Acti9 or third-party distribution boards without crowding.

Integration notes

The toggle control gives local ON/OFF indication.

MPN
A9N1P25BIN