Skip to main content
Schneider Electric A9N1P50CIN

Schneider Electric A9N1P50CIN Acti9 xC60 MCB, 50 A, 1P, C Cu

MPN A9N1P50CIN
Active

Schneider Electric Acti9 xC60, miniature circuit-breaker, 1P, 50 A, C curve, 10 kA Icu at 240 V AC, clip-on 35 mm DIN rail, IS/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N1P50CIN key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz 12...48 V DC 60 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to IS/IEC 60947-2
Breaking capacity10 kA Icu at 220...240 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 12...48 V DC conforming to IS/IEC 60947-2 6 kA Icu at 60 V DC conforming to IS/IEC 60947-2
Utilization categoryCategory A conforming to IS/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C

All specifications

A9N1P50CIN additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth77.5 mm
Width18 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

Acti9 xC60 50 A MCB — panel-builder commissioning notes

The C curve means magnetic tripping occurs at 8 x In (±20 %), so the breaker holds through motor inrush and transformer energisation but clears a hard short fast. For a 50 A circuit, that is a magnetic pickup between roughly 320 A and 480 A — typical for general-purpose distribution feeding mixed resistive and light inductive loads. Breaking capacity is 10 kA Icu at 220…240 V AC (50/60 Hz) per IS/IEC 60947-2, with a 15 kA Icu rating at 12…48 V DC and 6 kA Icu at 60 V DC. The standard certifies the breaker for isolation (suitability for isolation: yes) and assigns it utilisation category A — meaning it is not intended for frequent switching of motor loads but for cable and equipment protection in distribution. The IP20 finger-safe enclosure is adequate for enclosed distribution boards; no washdown rating is claimed.

Lifecycle and compliance — current production, tender-ready

The A9N1P50CIN carries a lifecycle stage of current, per the manufacturer's classification. It remains an active catalogue number within the Acti9 range, fully compliant with IS/IEC 60947-2 and tropicalised to IEC 60068-1 (class 2). For tender submissions requiring a traceable, in-production MCB with a published standard, this part meets the documentation threshold without a substitution note.

MPN
A9N1P50CIN