Skip to main content
Schneider Electric A9N21540

Schneider Electric A9N21540 iDPN MCB, 32 A, Curve B, 1P+N, C

MPN A9N21540
Obsolete

Schneider Electric Clario iDPN miniature circuit breaker, A9N21540, 32 A rated current, Curve B, 1P+N, 4500 A breaking capacity at 230 V AC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N21540 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50/60 Hz between phase and neutral
Insulation voltage ui400 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity4500 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...70 °C

All specifications

A9N21540 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-1
ColorWhite
Depth78 mm
Width18 mm
Height81 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

What this MCB does on the rail

The Schneider Electric A9N21540 is a 32 A iDPN miniature circuit breaker from the Clario range, wired 1P+N for single-phase distribution boards. Curve B trips magnetically between 3 and 5 times rated current (96–160 A), so it catches short-circuit faults fast on resistive or lighting loads where inrush is low — think heater banks, general socket circuits, control transformers. The 4500 A Icn breaking capacity at 230 V AC (EN/IEC 60898-1) handles typical domestic and light commercial fault levels; if your panel sees higher prospective short-circuit current, you'd step up to a higher-rated MCB or add a backup fuse upstream.

Clip-on mount to standard DIN rail, 18 mm width (2 x 9 mm pitches) — one module wide, so it slots into a crowded enclosure without eating up spare ways. Neutral on the left, tunnel terminals accept 0.33–16 mm² rigid or 0.33–10 mm² flexible; strip 13 mm, torque to 2 N·m. IP20 finger-safe front, but the back and terminals are live when installed — panel builders treat this as a standard enclosed MCB, not a sealed unit for washdown zones.

Curve B means the magnetic release acts at 3–5× In — lower than Curve C (5–10× In) — so it's a better match for circuits without motor or transformer inrush. The 4500 A breaking capacity at 230 V AC is the Icn per EN 60898-1; that's the rated short-circuit capacity the breaker can clear without damage. Pollution degree 3 (IEC 60947-1) means it's rated for conductive environments typical of distribution panels — no special coating needed for normal indoor use. Tropicalisation class 2 per IEC 60068-1 covers 95 % RH at 55 °C, so it holds up in humid plant rooms or coastal sites without derating.

MPN
A9N21540