Skip to main content
Schneider Electric A9Q44340

Schneider Electric A9Q44340 Acti9 Vigi iC60 RCD, 3P, 40A, 30

MPN A9Q44340
Active

Schneider Electric Acti9 series, Vigi iC60 add-on residual current device, 3P, 40 A, 300 mA, Type AC, instantaneous, 230...415 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9Q44340 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth73.5 mm
Width63 mm
Height91 mm
Operating temperature-5...60 °C

Product details

The A9Q44340 is a voltage-independent add-on residual current device (RCD) from the Acti9 Vigi iC60 family — clips onto the outgoing side of a compatible iC60 MCB to add earth-leakage protection without extra wiring. The 40 A rated current and 300 mA sensitivity mean it's sized for sub-distribution or feeder circuits where the load draws up to 40 A and you need a higher trip threshold to avoid nuisance tripping from leakage in long cable runs or industrial loads. Type AC detection handles sinusoidal AC residual currents only — fine for general lighting, socket outlets, and resistive loads, but not for pulsed or DC-ripple waveforms from VFDs, UPS, or EV chargers. The 230...415 V AC operational voltage covers single-phase and three-phase networks within that range. Voltage-independent tripping means the RCD disconnects even if the phase voltage collapses — a safety advantage for circuits where loss of neutral could otherwise mask a fault.

Clip-on mounting on standard DIN rail — snaps directly onto the rail beside or downstream of the iC60 MCB. The plug-in electrical connection to the MCB means no additional phase wiring; the RCD draws its supply through the MCB's outgoing terminals. Occupies 7 modules of 9 mm pitch, so 63 mm total width. Depth of 73.5 mm fits standard distribution boards and enclosures; verify gland-plate clearance if the board is shallow. IP20 finger-safe for enclosed panels; IP40 when installed in a modular enclosure. Tightening torque 3.5 N.m.

MPN