Skip to main content
Schneider Electric A9R14240

Schneider Electric A9R14240 Acti9 iID RCCB, 40 A, 300 mA, Ty

MPN A9R14240
Active

Schneider Electric Acti9 iID, residual current circuit breaker RCCB, 2P, 40 A, 300 mA Type AC, 220-240 V AC, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9R14240 specifications
ParameterValue
Control typeToggle
Voltage220...240 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth73.5 mm
Width36 mm
Height91 mm
Electrical life cyclesAC-1: 15000 cycles
Mechanical life cycles20000 cycles
Operating temperature-5...60 °C

Product details

The Schneider Electric A9R14240 is a 2-pole residual current circuit breaker (RCCB) from the Acti9 iID range, rated for 40 A continuous current with 300 mA earth-leakage sensitivity, Type AC, for 220-240 V AC 50/60 Hz networks. Let me show you why the ratings matter for a panel build: the 300 mA sensitivity means it's sized for general distribution protection — not for personal shock protection (that's the 30 mA class) — so it's a fit for submain or feeder circuits where you want ground-fault isolation without nuisance tripping on normal equipment leakage.

Rated breaking and making capacity is 1500 A (both Idm and Im) per EN/IEC 61008-1. That's the standard interrupting rating for this class of RCCB — it's designed for fault currents typical in final distribution, not high-fault service-entrance duty. The 250 A surge current (8/20 µs impulse) tells you it can handle lightning-induced transients on the line side without welding the contacts shut. Voltage-independent tripping is a detail worth flagging: the residual current detection circuit doesn't need a separate power supply — it steals energy from the fault itself, so the RCCB trips even if the neutral is lost upstream. That's good for fail-safe behavior, but it also means the trip characteristic doesn't change if the line voltage sags.

Installation details

The toggle handle has a contact position indicator (green/red band) and accepts a padlocking device for lockout/tagout. Electrical durability is 15000 cycles under AC-1 resistive load; mechanical durability is 20000 cycles.

MPN
A9R14240