Skip to main content
Schneider Electric A9R16492

Schneider Electric A9R16492 Acti9 RCCB-ID, 125 A 4P Type AC

MPN A9R16492
Active

Schneider Electric Acti9 RCCB-ID, residual current circuit breaker, 4P, 125 A, Type AC, 500 mA, 400 V AC, 50 Hz, 35 mm DIN rail.

$930.28 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9R16492 specifications
ParameterValue
Control typeToggle
Voltage400 V AC 50 Hz conforming to IEC/EN 61008-1 400 V AC 50 Hz conforming to IEC/EN 61008-2-1
Insulation voltage ui400 V AC 50 Hz conforming to IEC/EN 61008-1 400 V AC 50 Hz conforming to IEC/EN 61008-2-1
Terminal pitch18 mm between phases
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3
ColorGrey
Depth76 mm
Width72 mm
Height86 mm
Electrical life cycles2000 cycles
Mechanical life cycles5000 cycles
Operating temperature-25...40 °C

Product details

The Schneider Electric A9R16492 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 range, rated 125 A at 400 V AC, 50 Hz. It provides earth-leakage protection for outgoing circuits in a distribution board, tripping instantaneously when leakage current exceeds 500 mA.

At 125 A and 400 V, this RCCB handles the full incoming supply for a large sub-distribution board or a high-load outgoer — think a commercial kitchen, a workshop, or a bank of HVAC units. The 500 mA sensitivity is a deliberate choice: it's above the 30 mA threshold used for personal shock protection, so it's intended for equipment protection or fire prevention, not direct human contact. The instantaneous trip (no intentional delay) means it clears faults fast, but selectivity with downstream 30 mA RCDs requires careful coordination — the 500 mA device will trip first on a high-impedance fault. Breaking capacity is rated at Im = 1250 A at both 400 V and 230 V, per IEC/EN 61008-1 and 61008-2-1. The 8/20 µs impulse withstand of 250 A means it survives surge currents from lightning or switching transients without nuisance tripping. The storage temperature range of -40 to 85 °C covers most warehouse and transport conditions, though the operating ambient during service will be lower.

The 4-pole body occupies 8 x 9 mm pitches (72 mm total width), with the neutral on the left. Depth is 76 mm, height 86 mm — check gland plate clearance if the enclosure is shallow. Tunnel-type terminals accept up to 50 mm² rigid or 35 mm² flexible cable; wire stripping length is 11 mm, tightening torque 3 N·m. The IP20 body is fine for enclosed panels; the modular enclosure option gives IP40 for the front face. Padlockable toggle and a red/green trip indicator give clear local status — the contact position indicator shows whether the RCCB is on, off, or tripped, which speeds fault isolation on a multi-way board.

MPN