Schneider Electric A9Y71625

Schneider Electric A9Y71625 Acti9 Vigi iCG40, 25 A 300 mA Ty

MPN A9Y71625
Active

Schneider Electric Acti9 Vigi iCG40 add-on residual current device, 1P+N, 25 A, 300 mA Type A, instantaneous, voltage independent, DIN rail clip-on, 2-module width.

$251.48 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9Y71625 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 61009-2-1
ColorWhite
Depth74 mm
Width36 mm
Height102.5 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

It provides earth-leakage protection for the downstream circuit without replacing the existing MCB — a modular approach that keeps the breaker's overcurrent and short-circuit ratings intact while adding the RCD function. Rated 25 A continuous current with 300 mA Type A earth-leakage sensitivity, it trips instantaneously on fault and is voltage independent, meaning it operates even if the supply voltage collapses during a ground fault.

The 300 mA sensitivity is a common choice for group incomer or sub-distribution protection where nuisance tripping from normal leakage (cable capacitance, filter Y-caps) must be avoided. The instantaneous trip characteristic means no intentional time delay; the RCD clears within 200 ms per EN/IEC 61009-2-1, which is the standard for this class. Voltage-independent tripping is a reliability advantage: the RCD stores enough energy from the fault current itself to open the contacts, so a lost neutral or sagging supply won't disable protection.

The device occupies 2 x 9 mm pitches (18 mm width), matching the 1P+N module footprint. It connects to the upstream MCB via screw terminals — tunnel-type terminals accepting 1–16 mm² rigid or 1–10 mm² flexible conductors, tightened to 2 N·m. A fault-indication flag provides local visual status.

MPN
A9Y71625