Schneider Electric A9Y75640

Schneider Electric A9Y75640 Acti9 Vigi iCG40 RCD, 40A, 300mA

MPN A9Y75640
Active

Schneider Electric Acti9 Vigi iCG40 add-on residual current device, A9Y75640, 1P+N, 40 A, 300 mA Type A-SI, instantaneous, 230 V AC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9Y75640 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 61009-2-1
ColorWhite
Depth74 mm
Width36 mm
Height102.5 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The A9Y75640 is a voltage-independent add-on residual current device (RCD) from the Acti9 Vigi iCG40 series, designed to clip onto the outgoing side of a compatible Acti9 MCB. It provides earth-leakage protection for a single-phase 230 V AC circuit at 40 A rated current, with a 300 mA sensitivity. The Type A-SI (Super Immunised) classification means it handles pulsed DC fault currents and resists nuisance tripping from high-frequency harmonics or transient surges common on modern electronic loads — think variable-speed drives, UPS systems, or LED lighting banks where standard Type A or AC RCDs can false-trip. The instantaneous response (no intentional time delay) suits it as a group incomer protecting a sub-distribution board rather than individual final circuits. The 40 A rating matches the upstream MCB capacity, so coordination is straightforward: the RCD and MCB share the same current rating, and the voltage-independent trip mechanism means the RCD operates even if the neutral is lost — a safety-relevant detail for group incomer duty. The 300 mA sensitivity is deliberately less sensitive than 30 mA; it is sized for equipment protection and fire prevention rather than personal shock protection, which is why it sits at the group incomer position per the device location spec.

The tunnel-type terminals accept 1 to 16 mm² rigid or 1 to 10 mm² flexible conductors on top; wire stripping length is 14 mm. The electrical connection to the MCB is via screws, so the RCD is mechanically ganged to the breaker — no extra busbar required. IP20 for the terminals, IP40 for the modular enclosure inside a panel. Ambient operating range -25 to 60 °C, storage -40 to 85 °C, with 95% relative humidity at 55 °C and operating altitude up to 2000 m.