Schneider Electric A9Y85725

Schneider Electric A9Y85725 Acti9 Vigi iC40 RCD, 25 A, 300 m

MPN A9Y85725
Active

Schneider Electric Acti9 Vigi iC40 add-on residual current device, A9Y85725, 25 A, 300 mA sensitivity, Type A-SI, 3P+N, 400 V AC, DIN rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9Y85725 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 61009-2-1
ColorWhite
Depth74 mm
Width90 mm
Height99.5 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The Schneider Electric A9Y85725 is an Acti9 Vigi iC40 add-on residual current device (RCD) rated for 25 A continuous current and 300 mA earth-leakage sensitivity. It clips onto the outgoing side of a compatible Acti9 MCB via screws, making it a voltage-independent, instantaneous-trip RCD block for 3P+N circuits at 400 V AC, 50/60 Hz. The Type A-SI (Super Immunised) classification means it handles pulsed DC fault currents and resists nuisance tripping from high-frequency leakage typical of VFDs or UPS systems — a solid fit for mixed-load panels where standard Type A might false-trip.

Rated 25 A [In] and 300 mA sensitivity: this RCD protects a 25 A outgoing circuit against earth faults up to 300 mA — typical for general-purpose socket outlets or small distribution sub-circuits in commercial or light industrial panels. The 400 V AC operational voltage (Ue) matches standard three-phase four-wire networks. Voltage-independent tripping means the RCD breaks the circuit on residual current alone, even if the mains voltage collapses — a safety advantage over electronically-triggered units in fault conditions. Instantaneous time delay gives no intentional delay, so it trips within the standard IEC 61009-2-1 curve — use it where selectivity with upstream delayed RCDs is not required. Pollution degree 3 per EN/IEC 61009-2-1 and IP20/IP40 enclosure suit it for clean, dry indoor panel environments.

Clip-on DIN rail mount. 4 x 9 mm pitches wide. Neutral position left. Tightening torque 2 N·m. Wire strip length 14 mm. Local fault indication — a mechanical flag or window shows tripped status without needing to power the circuit.