Schneider Electric A9Y87625

A9Y87625 Acti9 Vigi iC40 25A 30mA RCBO, 1P+N

MPN A9Y87625
Active

Schneider Electric Acti9 Vigi iC40 A9Y87625, add-on residual current device, 1P+N, 25 A, 30 mA, Type A-G, 230 V AC, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9Y87625 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 61009-2-1
ColorWhite
Depth74 mm
Width36 mm
Height95 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

It protects a single outgoing 1P+N circuit at 230 V AC, 50/60 Hz, with a rated current of 25 A and an earth-leakage sensitivity of 30 mA. The voltage-independent tripping mechanism means the RCD operates without needing a separate power supply or electronic circuit — the fault current itself energizes the trip solenoid, which improves reliability in degraded voltage conditions.

Integration into a panel

The add-on design occupies one modular space to the right of its paired MCB; the two units are linked by screws through the side terminals. Bottom tunnel terminals accept 1…16 mm² rigid or 1…10 mm² flexible cable, stripped 14 mm, tightened to 2 N·m. The white housing carries a local fault-indication flag that shows after a trip, aiding troubleshooting without a meter.

Rated insulation voltage 400 V AC, impulse withstand 4 kV — both conforming to EN/IEC 61009-2-1, which governs the safety and performance of residual current operated circuit-breakers with integral overcurrent protection (RCBOs). Ambient operating range -25…60 °C, storage -40…85 °C, with 95 % relative humidity at 55 °C. Maximum operating altitude 2000 m. The electrical endurance is rated at 10,000 cycles, mechanical at 20,000 cycles — figures that reflect the device's intended use as a protective device with infrequent manual operation.