Skip to main content
Schneider Electric ATV1200A17156666

Schneider ATV1200A17156666 Altivar 1200 VFD, 1434 kW

MPN ATV1200A17156666
Active

Schneider Electric Altivar 1200 series, ATV1200A17156666 medium-voltage variable frequency drive, 1434 kW motor power, 2970...3630 V supply, 36-pulse diode rectifier, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV1200A17156666 specifications
ParameterValue
Input type36 pulse diode rectifier bridge
Protection typeGround fault protection: drive
Coil voltage220 V
Current150 A
IP ratingIP41 / IP31 / IP42
Temp storage max60 °C
Temp storage min-10 °C
Temp operating max50 °C
Temp operating min0 °C
Storage temperature-10...60 °C
Pollution degreePollution degree 2
Depth1600 mm (high efficiency) 1500 mm (standard efficiency)
Width3960 mm (standard efficiency) 4260 mm (high efficiency)
Height2740 mm high efficiency 2740 mm standard efficiency
Operating positionVertical +/- 10 degree
Operating temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)

Product details

What this drive delivers at the motor shaft

The ATV1200A17156666 is a medium-voltage VFD rated for 1434 kW motor output, drawing 1715 kVA apparent power from a 2970 to 3630 V supply. That's not a derated figure — it's the full continuous rating for an asynchronous motor load, so the drive handles the full pump, fan, or conveyor duty without oversizing the cabinet. The 36-pulse diode rectifier input keeps line-side harmonics low enough that you can skip a separate harmonic filter in most installations — the integrated EMC filter handles the conducted emissions side.

Overload profile and fault handling

Standard overload rating holds 1.2× In for 60 seconds and 1.5× In for 3 seconds; switch to high overload mode and it handles 1.5× In for 60 seconds and 1.85× In for 3 seconds. That extra headroom matters when you're starting a high-inertia load or clearing a downstream fault without tripping the drive. Prospective line short-circuit current rating is 31.5 kA for 150 ms — the drive withstands that fault pulse without internal damage, so upstream breaker coordination can be set to the drive's withstand curve rather than forcing a full-selectivity scheme. Ground fault protection is integrated into the drive itself, not reliant on an external relay. That saves a panel component and reduces wiring.

Physical footprint and installation constraints

The drive ships as a floor-standing enclosure. Standard-efficiency version measures 3960 mm wide × 1500 mm deep × 2740 mm high; the high-efficiency variant is wider at 4260 mm and deeper at 1600 mm. That's a full cabinet row — plan for fork-truck access during installation and a 300 mm clearance behind for the forced-convection airflow path. Cooling air volume is 29,900 m³/h for standard efficiency, 33,200 m³/h for high efficiency. The room ventilation system needs to handle that exhaust heat — don't let the ambient temperature creep above the 0 to 90 % humidity envelope. Operating altitude up to 1000 m is full rating; above that, derate 0.6 % per 100 m up to 2000 m. If the installation is above 2000 m, you need a custom engineering review — the drive's pollution degree 2 rating assumes a controlled environment.

Control wiring and I/O complement

Four software-configurable analogue inputs (0-20 mA / 4-20 mA, 24 V max, 250 Ω impedance) and one analogue output of the same type. Six discrete inputs standard, expandable to ten with an option board. That's enough for basic speed reference, feedback, and run/stop commands without an extra I/O slice. Control supply is 220 V AC at 3 kVA, external. The cooling fan runs on a separate 380 V AC supply — keep those circuits independent so a fan failure doesn't take down the control logic.

Compliance and lifecycle status

CE marked, designed to EN/IEC 60204-11, 60529, 61800-3, 61800-4, and 61800-5-1. Dielectric strength is 20 kV AC between earth and power terminals — that's the insulation coordination for a medium-voltage drive connected directly to a 3.3 kV bus. Lifecycle stage is listed as current — meaning the manufacturer still supports it as an active catalogue item.

MPN
ATV1200A17156666