Schneider Electric C104TM025C

Schneider C104TM025C ComPacT NSX Trip Unit, TM-D, 25 A, 4P

MPN C104TM025C
Active

Schneider Electric ComPacT NSX100...250 series, TM-D thermal-magnetic trip unit, 25 A at 50 °C, 4 poles 4D, LI protection, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C104TM025C specifications
ParameterValue
Trip unit typeThermal-magnetic
Main product or component typeTrip unit
Voltage690 V AC 50/60 Hz 750 V DC
IP ratingIP40
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947-1
ApplicationDistribution
Operating temperature-25...70 °C

Product details

It's the replaceable protection element that determines the breaker's overload and short-circuit response — not the breaker frame itself. Rated 25 A at 50 °C, it protects 4 poles in a 4D configuration, meaning all four poles are monitored and the neutral is fully protected at 1 x Ir. The trip unit carries LI protection: thermal L for overload, magnetic I for short-circuit. The instantaneous magnetic pickup is fixed at 300 A, and the long-time thermal pickup is adjustable from 0.7 to 1 x In.

The adjustable long-time pickup (Ir) from 0.7 to 1 x In lets you fine-tune the overload threshold without swapping the trip unit: at 0.7 x In you get a 17.5 A effective setting, at 1.0 x In you get the full 25 A. The fixed instantaneous pickup at 300 A means the magnetic trip clears short-circuits above that level — about 12 x In — which is typical for distribution protection where you want some selectivity downstream. The 4D protected poles with neutral protection at 1 x Ir means the neutral pole is fully rated and monitored — not just switched. This matters for 4-wire systems where the neutral carries load and a fault on any phase needs to be cleared. The fixed long-time delay (tr) gives a 120...400 s band at 1.5 x In and 15 s at 6 x Ir — that's a standard thermal curve for distribution, not for motor starting. If you're protecting a motor load, you'd want a different trip unit with a longer delay.

MPN
C104TM025C