Skip to main content
Schneider Electric C11N34V025L

C11N34V025L ComPacT NSXm Earth Leakage Breaker, 25 A, 50 kA

MPN C11N34V025L
Active

Schneider Electric ComPacT NSXm, C11N34V025L, earth leakage circuit breaker, 3P, 25 A, 50 kA at 415 V AC, MicroLogic 4.1 trip unit, integrated earth leakage.

$777.35 – $1,335.42 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C11N34V025L key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm with spreaders 27 mm without spreaders
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

C11N34V025L additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
ColorGrey (RAL 7016)
Depth80 mm
Width108 mm
Height144 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Safety categoryN 50 kA 415 V AC
Operating temperature-25...70 °C

Product details

The C11N34V025L is a Schneider Electric ComPacT NSXm earth leakage circuit breaker — a 3-pole, 25 A unit with an electronic MicroLogic 4.1 trip unit and integrated earth-leakage protection. It's built to EN/IEC 60947-2, Category A utilisation, meaning it's rated for distribution duty: protecting cables and busbars, not motor starts.

That matters on a panel feeding a cyclic load like a compressor bank. Integrated earth leakage means you get adjustable sensitivity from 30 mA to 5 A, class A or AC. No separate RCCB module to wire in — saves two modules of DIN width and one interconnection. The Everlink terminals accept up to 95 mm² rigid copper or 70 mm² fine-stranded, so it'll take a feeder cable without a reducer lug. IP40 front face, IK07 impact rating — standard for a distribution board, not for a washdown zone.

Mounts on a backplate — not DIN rail — so you're bolting it to a panel or chassis. 9-module pitch, 108 mm wide, 144 mm tall, 80 mm deep. Connections are front-facing top and bottom, which wires up clean in a row of breakers. The flag indicator (green) shows auxiliary contact presence without opening the cover.

Current production — no phase-out notice on record.

MPN
C11N34V025L