Skip to main content
Schneider Electric C2547E250

C2547E250 ComPacT NSX MicroLogic 7.2 E Trip Unit, 250 A

MPN C2547E250
Active

Schneider Electric ComPacT NSX250, MicroLogic 7.2 E trip unit, 250 A at 40 °C, 4P, LSIR protection, integrated earth-leakage Class A, IEC 60947-2.

$16.58 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C2547E250 specifications
ParameterValue
Display typeLCD display
Trip unit typeElectronic
Main product or component typeTrip unit
Voltage440 V AC 50/60 Hz
IP ratingIP40
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C2547E250 is a MicroLogic 7.2 E electronic trip unit for the ComPacT NSX250 molded-case circuit breaker platform. It's the brain that decides when to hold, when to trip, and what data to log — rated 250 A at 40 °C for 4-pole distribution feeders. This is the version with integrated earth-leakage protection (Class A) and full LSIR curves: long-time, short-time, instantaneous, and residual current.

The Ir adjustment range (100–250 A) lets you down-rate the trip point to match the actual load without swapping hardware, critical when a feeder is oversized for future expansion but needs to protect today's 180 A load. LSIR protection means you get four coordinated curves: L (long-time, adjustable 15–400 s at 1.5×Ir) for overload, S (short-time, 0–0.4 s with I²t on/off) for selective coordination downstream, I (instantaneous, adjustable) for bolted faults, and R (earth-leakage, integrated Class A) for ground faults. The 20-minute thermal memory before and after tripping means a reclose after a near-trip won't let the next overload cook the cable — the trip unit remembers the heat history. Neutral protection settings are selectable: 0.5×Ir (3D+N/2), 1×Ir (4D), 1.6×Ir (3D+OSN), or no protection.

Deployment context

This trip unit snaps into a ComPacT NSX250 fixed-mount breaker in a distribution panelboard or switchboard. The IP40 front face (IEC 60529) is fine for indoor electrical rooms but not washdown areas — keep it dry. The LCD display shows real-time energy metering, demand current, power quality, and event logs, so you can read load profiles without a separate meter or gateway.

Current production — the MicroLogic 7.2 E is an active catalog item in Schneider's ComPacT NSX line. No end-of-life notice on this variant.

MPN
C2547E250