Skip to main content
Schneider Electric C6334A570

Schneider Electric C6334A570 ComPacT NSX MicroLogic 4.3 AL T

MPN C6334A570
Active

Schneider Electric ComPacT NSX series, MicroLogic 4.3 AL electronic trip unit, 570 A at 40 °C, 3P, EN/IEC 60947-2, integrated earth-leakage Class A, LSoI protection.

$16.17 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C6334A570 specifications
ParameterValue
Trip unit typeElectronic
Main product or component typeTrip unit
Voltage440 V AC 50/60 Hz
IP ratingIP40
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947-1
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C6334A570 is a MicroLogic 4.3 AL electronic trip unit for the Schneider Electric ComPacT NSX400...630 molded-case circuit breaker range. It is the replaceable protection logic module that plugs into the breaker — you swap the trip unit, not the whole breaker, to change the protection profile or rating. Rated 570 A at 40 °C, it is sized for distribution feeders in the upper end of the NSX frame. The trip unit provides LSoI protection: long-time overload (L), short-time short-circuit with fixed delay (So), and instantaneous short-circuit (I). The long-time pickup (Ir) is adjustable from 250 to 570 A across nine settings, so the same unit covers a range of cable or transformer ratings without a hardware swap. Short-time pickup (Isd) adjusts from 1.5 to 10 times Ir; instantaneous pickup (Ii) is fixed at 6900 A.

Integrated earth-leakage — what Class A means on the line

This is the AL variant, meaning it carries integrated earth-leakage protection rated Class A per IEC 60755. Class A detects sinusoidal AC residual currents plus pulsating DC — the common waveform from rectified loads, VFDs, and switched-mode supplies that a plain AC-sensitive relay misses. Sensitivity (IΔn) is adjustable via the rotary switch, and the time delay (Δt) can be set to 0 ms, 60 ms, 150 ms, 500 ms, or 1 s. Earth leakage can be disabled entirely by switching IΔn to OFF. The trip unit is electronic, not thermal-magnetic. This matters for motor or transformer feeders where re-acceleration inrush follows a trip.

Standards, approvals, and deployment context

It carries Pollution Degree 3 per IEC 60947-1 — suitable for industrial enclosures where conductive pollution (dust, condensation) is expected.

Sourcing and procurement note

For a BOM line carrying C6334A570, the key fit confirmation is the 570 A rating at 40 °C and the 3P 3D pole configuration. The trip unit is fixed-mount and mates with any ComPacT NSX400...630 frame breaker.

MPN