Skip to main content
Schneider Electric EVS32H3NW20

Schneider Electric EVS32H3NW20 EasyPact EVS Circuit Breaker,

MPN EVS32H3NW20
Active

Schneider Electric EasyPact EVS series, EVS32H3NW20, 3-pole drawout circuit breaker, 3200 A rated current, 65 kA Icu at 440 V AC, electronic trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS32H3NW20 key specifications
ParameterValue
Control typeElectrically operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS32H3NW20 additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The Schneider Electric EVS32H3NW20 is a 3-pole drawout circuit breaker from the EasyPact EVS range, rated 3200 A at 40 °C with an electronic EVS Trip System2.0 trip unit. It carries a 65 kA Icu breaking capacity at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2. The 1000 V AC rated insulation voltage (Ui) and pollution degree 4 per IEC 60664-1 suit it for main distribution in industrial switchgear where high fault currents and harsh environments are the norm.

Category B utilization means it's intended for distribution with selective coordination — the 20-minute thermal memory before and after tripping helps coordinate with downstream devices by retaining the thermal state during a reclose interval.

Deployment context

This breaker mounts on a rail base plate inside a switchgear cubicle — the drawout design means the fixed portion (cradle) stays wired to the bus, and the moving portion (the breaker itself) racks in and out. The 3-pole 3d protected poles with contact position indicator give visual confirmation of open/closed state, useful for LOTO procedures.

MPN
EVS32H3NW20