Skip to main content
Schneider Electric EZC100H1015

Schneider EZC100H1015 EasyPact EZC circuit breaker, 1-pole, 15 A, 125 V DC/AC

MPN EZC100H1015
Active

Schneider EZC100H1015 Easypact Ezc — now discontinued. Supplied from remaining channel stock; full specifications, lifecycle and same-series options are below.

$35.67 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC100H1015 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

EZC100H1015 additional specifications
ParameterValue
Temp storage min-35 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Depth60 mm
Width25 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

Overview

The EZC100H1015 is a Schneider EasyPact EZC100H series 1-pole circuit breaker with a TM-D thermal-magnetic trip unit rated 15 A at 50 °C. It operates on 125 V DC/AC at 60 Hz and is fixed-mounted with IP20 finger-safe protection. The breaker provides short-circuit and overload protection for distribution applications and carries an H-class breaking capacity. It is an active, in-production part.

Alternatives & selection

Compared to the 4-pole EZC100H4016 (16 A, 550 V), the EZC100H1015 uses a single pole and a lower 125 V supply, making it suitable for single-phase or DC branch circuits rather than three-phase distribution. The 15 A trip rating versus 16 A is a minor difference, but the pole count and voltage rating are the primary selection gates — the EZC100H1015 cannot replace a 4-pole breaker in a three-phase panel without rewiring.

MPN
EZC100H1015