Skip to main content
Schneider Electric EZS630F3600

EZS630F3600 EasyPact EZS 600 A 3P Circuit Breaker, 40 kA

MPN EZS630F3600
Obsolete

Schneider Electric EasyPact EZS series, EZS630F3600, 3-pole thermal-magnetic circuit breaker, 600 A at 40 °C, breaking capacity 40 kA Icu at 240 V AC, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZS630F3600 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to EN/IEC 60947-2 400 V AC 50/60 Hz conforming to GB 14048.2
Insulation voltage ui690 V conforming to EN/IEC 60947-2
Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 380/400 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 40 kA Icu at 220/230 V AC 50/60 Hz conforming to GB 14048.2 35 kA Icu at 440 V AC 50/60 Hz conforming to GB 14048.2
IP ratingIP40
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

EZS630F3600 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth110 mm
Width182 mm
Height257 mm
Electrical life cycles8000 cycles 415 V In/2 conforming to EN/IEC 60947-2 8000 cycles 400 V In conforming to GB 14048.2
Mechanical life cycles15000 cycles conforming to EN/IEC 60947-2 10000 cycles conforming to GB 14048.2
Operating temperature-35...70 °C

Product details

The breaking capacity of 40 kA Icu at 220/240 V AC and 36 kA Icu at 380/400 V AC (both per EN/IEC 60947-2) tells you the maximum fault current it can safely interrupt at those voltages. The thermal-magnetic trip provides overload protection (thermal element) and short-circuit protection (magnetic element), with fixed long-time pickup at 1 In — no field adjustment on the trip curve.

This breaker mounts fixed to a backplate — no DIN-rail clip, so plan for a drilled or tapped mounting surface. Connection pitch is 45 mm, neutral position is left, and the toggle control is front-accessible. IP40 protection keeps dust out but doesn't seal against moisture — keep it indoors or in a weatherproof cabinet.

MPN
EZS630F3600