Skip to main content
Schneider Electric GV4L80B6

Schneider GV4L80B6 TeSys GV4 Motor Circuit Breaker, 80 A, 3P

MPN GV4L80B6
Active

Schneider Electric TeSys GV4 motor circuit breaker, GV4L80B6, 80 A rated current, 3-pole, 50 kA breaking capacity at 240 V AC, rotary handle control.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4L80B6 key specifications
ParameterValue
Control typeRotary handle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch27 mm without spreaders 35 mm with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C

All specifications

GV4L80B6 additional specifications
ParameterValue
Pollution degree3
ColorGrey (RAL 7016)
Depth165 mm
Width81 mm
Height155 mm
Electrical life cycles14000 cycles for AC-3 at 440 V In/2 7000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

What the 80 A rating means for your motor circuit

The GV4L80B6 is a 3-pole motor circuit breaker rated at 80 A continuous current, sized for a 37 kW motor at 400 V AC or 45 kW at 500 V AC — the power figures shift with supply voltage, so match the line voltage to the correct kW column in the spec table. The 80 A is the thermal continuous rating; the magnetic trip is set to 480–1120 A, catching short-circuit faults while letting motor inrush pass. This is a Category A breaker per IEC 60947-2 and AC-3 rated per IEC 60947-4-1, meaning it's built for direct motor switching with no intentional delay. Breaking capacity hits 50 kA at 240 V AC, 25 kA at 415 V, and 10 kA at 500 V — enough for most industrial panel fault levels, but verify the available fault current at your point of common coupling.

Where this part fits in the panel

Mounts in any position — no derating needed for orientation. The 81 mm width and 155 mm height fit standard DIN-rail spacing; depth is 165 mm including the rotary handle throw. Connection pitch is 27 mm without spreaders, 35 mm with, so plan the gland plate and busbar layout accordingly. Terminals accept lugs or ring terminals; torque to 9 N·m for 16–95 mm² cable, 5 N·m for 1.5–10 mm². Climatic withstand conforms to IACS for marine-adjacent applications — relevant if the panel feeds a shipboard or offshore load.

Durability and switching life

Mechanical durability is 40,000 cycles. Electrical durability at AC-3 (motor load) is 7,000 cycles at rated current, 14,000 cycles at half current — the 7,000-cycle figure governs if the motor runs near the 80 A limit. Maximum operating rate is 25 cycles per hour, so it's not a high-speed jogging breaker but fine for normal start/stop duty on conveyors, pumps, or compressors. Power dissipation per pole is 6.1 W at full load; three poles add 18.3 W to the enclosure heat budget.

MPN
GV4L80B6