Skip to main content
Schneider Electric LV847292WW

Schneider Electric LV847292WW MicroLogic 6.0 Xi, MasterPacT,

MPN LV847292WW
Active

Schneider Electric MasterPacT, MicroLogic 6.0 Xi control unit, LSIG protection, 3P 4P, drawout, LCD display, 690 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV847292WW specifications
ParameterValue
Control typeWired control
Display typeLCD display - 128 x 96 pixels
Trip unit typeElectronic
Main product or component typeControl unit
Voltage690 V AC, +/- 10 %
Poles3
Temp operating max70 °C
Temp operating min-35 °C
Pollution degree3 conforming to IEC 60947-1
ApplicationEquipment protection, monitoring and control
Operating temperature-25...70 °C (operating) -35 °C (for start-up of product)

Product details

MicroLogic 6.0 Xi control unit for MasterPacT drawout breakers

The Schneider Electric LV847292WW is a MicroLogic 6.0 Xi electronic control unit for the MasterPacT range of drawout air circuit breakers. It provides LSIG protection — long-time, short-time, instantaneous, and ground-fault — with a trip unit rating selectable from 400 A up to 1600 A. The drawout mounting means the control unit and its breaker can be racked out for maintenance without disturbing line-side connections, a key feature for switchboard installations where uptime matters.

What the LSIG protection scheme means for coordination

LSIG covers the full protection curve: overload (long-time, ANSI 49), short-time delay (ANSI 51), instantaneous (ANSI 50), and earth fault (ANSI 51N). The long-time delay is adjustable in 0.5 s steps, which lets the engineer tune selectivity with downstream breakers. Zone selective interlocking (ZSI) is built in — when multiple MasterPacT breakers are linked, the faulted unit trips instantaneously while upstream units hold, reducing arc-flash energy at the fault point. For a site electrical engineer reviewing a coordination study, this is the feature that makes the difference between a selective and a cascading trip.

Metering and display: what you can read from the front panel

The 128 x 96 pixel LCD shows a full electrical instrumentation suite: per-phase and average currents, neutral and ground-fault current, phase-to-phase and phase-to-neutral voltages, active/reactive/apparent power and energy, power factor, frequency, demand values, and harmonic distortion (THD) for both current and voltage. Measurement accuracy for current is ±0.5 % over the 40–1600 A range for MTZ1 frames. The control unit also logs events, alarms, maintenance data, and min/max instantaneous values with time stamps. This is not just a trip unit — it replaces a separate power meter in the same drawout cassette.

Environmental and installation constraints

Operating altitude goes to 5000 m with voltage derating above 560 V AC. Humidity tolerance is 95 % at 55 °C. The control unit is not approved for wet locations, so keep it in the dry switchgear room. EMC compliance covers electrostatic discharge, radiated fields, fast transients, surge (1.2/50 µs), and conducted RF, with conducted and radiated emissions at Class A per CISPR 22.

MPN
LV847292WW