Skip to main content
Schneider Electric MGN02363

MGN02363 Acti9 D0 Fuse-Switch Disconnector, 63 A, 3P

MPN MGN02363
Active

Schneider Electric Acti9 D0 series, MGN02363 fuse-switch disconnector, 3 poles, 63 A rated current, 230-400 V AC, 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN02363 specifications
ParameterValue
Main product or component typeFuse-switch disconnector
Voltage230...400 V AC 50/60 Hz
Insulation voltage ui400 V
Utilization categoryAC-22 A conforming to IEC 60947-3
IP ratingIP20
Temp storage max55 °C
Temp storage min-25 °C
Temp operating max40 °C
Temp operating min-5 °C
Storage temperature-25...55 °C
Depth68 mm
Width81 mm
Height88 mm
Electrical life cycles1500 cycles
Mechanical life cycles8500 cycles open-close
Operating temperature-5...40 °C

Product details

The MGN02363 is a Schneider Electric Acti9 D0 fuse-switch disconnector — three poles, rated 63 A, designed for 230-400 V AC 50/60 Hz circuits. The 3-pole form factor handles three-phase loads: a motor branch, a lighting distribution board, or a sub-feed from a main switchboard.

The 63 A rated current (In) and AC-22A utilisation category per IEC 60947-3 tell you this part is built for switching mixed resistive and inductive loads — not just isolating. AC-22A covers on-load making and breaking of circuits with a mix of resistive and inductive elements, which is the typical duty for a fuse-switch in a distribution panel feeding motor starters or lighting contactors. The 1500-cycle electrical endurance and 8500-cycle mechanical endurance give a realistic service life for a panel that sees a few switching operations per shift; it is not a daily-break disconnect for a production machine. Rated insulation voltage (Ui) is 400 V, and the rated impulse withstand voltage (Uimp) is 6 kV — that 6 kV figure is the surge it can survive without flashover, matching typical IEC 60947-1 coordination levels for a 400 V distribution panel. The operating temperature range of -5 to 40 °C is standard for indoor panels; storage from -25 to 55 °C covers shipping and warehouse conditions.

Terminal and fuse details

Screw-clamp terminals accept 1.5 to 35 mm² rigid or 1.5 to 25 mm² flexible cable; wire stripping length is 14 mm, and the tightening torque is 3 N·m. The fuse size is 15 x 36 mm, D02 fuse-link format — the GG and AM curves are both listed, so you can fit either a general-purpose gG fuse for cable protection or an aM fuse for motor-circuit short-circuit backup. The 9-mm pitch per pole means the 3-pole unit occupies 81 mm of DIN-rail width, which is the standard Acti9 D0 footprint.

MPN