Schneider Electric MGN25086

Schneider Electric MGN25086 C60H MCB, 16 A, D Curve, 1P, 15

MPN MGN25086
Obsolete

Schneider Electric C60H Multi9 miniature circuit breaker, MGN25086, 1-pole, 16 A, D curve, 15 kA breaking capacity at 240 V AC, thermal-magnetic trip, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN25086 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage240 V AC 50/60 Hz phase to neutral
Breaking capacity15 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 4 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN25086 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width18 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric MGN25086 is a C60H miniature circuit breaker from the Multi9 range, rated 16 A at 50 °C with a D curve and 1-pole construction. This thermal-magnetic MCB is designed for distribution applications where high inrush currents — motor starting, transformer energization, or lighting banks — demand a D-curve magnetic trip set at 12 x In ± 20 %.

For a 415 V AC phase-to-neutral supply, Icu drops to 4 kA and Ics to 2 kA. That matters when you're coordinating downstream protection in a panel where available fault current exceeds the lower rating — you need to verify the fault level at the breaker's location against these numbers. The D curve (12 x In magnetic trip) means the breaker holds through short-duration current spikes up to roughly 192 A before the solenoid trips instantaneously. Rated operational voltage is 240 V AC phase-to-neutral, 50/60 Hz. This is a 1-pole (1P) device protecting a single phase.

Standards, approvals, and isolation capability

It carries an IP20 finger-safe terminal enclosure once installed. It is marked suitable for isolation per EN/IEC 60947-2, with a clear contact position indicator (ON/OFF) on the toggle. That lets you use it as a visible-break disconnect for local isolation of a circuit during maintenance — no separate isolator needed.

MPN
MGN25086