Schneider MGN60887 C60N MCB, 63 A, 2P, C-Curve, 20 kA

MPN MGN60887
Obsolete

Schneider Electric Multi9 C60N, MGN60887, miniature circuit breaker, 63 A, 2-pole, C-curve, 20 kA Icu at 240 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60887 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

MGN60887 additional specifications
ParameterValue
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric MGN60887 is a C60N miniature circuit breaker from the Multi9 range, rated 63 A at 50 °C per EN/IEC 60947-2.

The C-curve trips magnetically at 8.5 x In (±20 %), so at 63 A that's roughly 536 A instantaneous pickup. That's sized for motor-starting inrush or transformer energization — a B-curve would nuisance-trip on those loads, while a D-curve would let a fault ride too long. It's not a one-shot device. The 10 kA Icu at 415 V and 6 kA at 440 V tell you the interrupting capability drops as voltage climbs; for a 400 V distribution board this breaker is fine on a 6 kA prospective fault level, but don't put it where the available fault current exceeds that. The IP20 finger-safe terminals are standard for enclosed gear; if the breaker lives exposed, you'll need a cover.

Mounting and wiring in the panel

Snaps onto 35 mm symmetrical DIN rail. Tunnel terminals accept 1.5 to 35 mm² flexible or rigid copper, with a 14 mm strip length and 3.5 N.m torque. That's enough lug for a 35 mm² feeder on the line side and 25 mm² downstream. Busbar compatible top or bottom, so daisy-chaining phases across a row is straightforward.