Schneider Electric RM4JA32Q

Schneider RM4JA32Q Current Measurement Relay, 1–15 A, 2 C/O

MPN RM4JA32Q
Obsolete

Schneider Electric Harmony RM4JA32Q industrial current measurement relay, 1–15 A AC/DC, 2 C/O output contacts, adjustable time delay 0.05–30 s, screw terminals, 80 x 45 x 78 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

RM4JA32Q specifications
ParameterValue
TypeCurrent measurement relay
Time delay typeAdjustable 0.05...30 s
Current2 A 24 V DC-13 158 °F (70 °C) IEC 60947-5-1/1991 2 A 24 V DC-13 158 °F (70 °C) VDE 0660 3 A 115 V AC-15 158 °F (70 °C) IEC 60947-5-1/1991 3 A 115 V AC-15 158 °F (70 °C) VDE 0660 3 A 24 V AC-15 158 °F (70 °C) IEC 60947-5-1/1991 3 A 24 V AC-15 158 °F (70 °C) VDE 0660 3 A 250 V AC-15 158 °F (70 °C) IEC 60947-5-1/1991 3 A 250 V AC-15 158 °F (70 °C) VDE 0660 0.1 A 250 V DC-13 158 °F (70 °C) IEC 60947-5-1/1991 0.1 A 250 V DC-13 158 °F (70 °C) VDE 0660 0.3 A 115 V DC-13 158 °F (70 °C) IEC 60947-5-1/1991 0.3 A 115 V DC-13 158 °F (70 °C) VDE 0660
IP ratingIP20 / IP50
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max65 °C
Temp operating min-20 °C
Storage temperature-40...185 °F (-40...85 °C)
Pollution degree3 IEC 60664-1
Depth3.1 in (80 mm)
Width1.8 in (45 mm)
Height3.07 in (78 mm)
Mechanical life cycles30000000 cycles
Operating positionAny position without derating
Operating temperature-4...149 °F (-20...65 °C)

Product details

What it is and what it guards

The RM4JA32Q is a Harmony current measurement relay from Schneider Electric — it watches for overcurrent or undercurrent conditions on a monitored line and trips its output contacts when the measured current crosses the set threshold. It covers six measurement ranges: 1–5 A AC/DC, 3–15 A AC/DC, and 300–1500 mA AC/DC, so it fits motor feeder monitoring, pump protection, or heater circuit supervision in a single device. Two C/O (changeover) relay contacts give you both a normally-open and normally-closed signal path per channel — enough to drive an alarm and a trip in the same relay.

Setting the trip point and delay

The adjustable time delay from 0.05 to 30 seconds lets you ride through inrush or transient events before the relay trips — critical for motor start-up or transformer energisation where a short overcurrent is normal. The output relay trips when measured current exceeds the set threshold (overcurrent) or falls below it (undercurrent), configurable by the front-panel dials. Maximum measuring cycle is 80 ms, so the relay responds fast enough for most protection schemes without nuisance tripping on sub-cycle noise.

Panel fit and environmental tolerance

The RM4JA32Q measures 80 mm deep, 45 mm wide, and 78 mm high — a compact DIN-rail footprint that fits standard control-panel enclosures without crowding adjacent devices. IP20 on the terminals and IP50 on the casing means it's protected against dust ingress inside a panel but not for washdown environments — keep it in a sealed cabinet. Screw terminals accept 1.5 mm² flexible with cable end or 2.5 mm² flexible without — standard for panel wiring up to 14 AWG.

MPN