ABB 3ABD00035951-D — AC Drive (VFD) 480V

ABB 3ABD00035951-D ACS880 Drive, 75 kW, 145 A

MPN3ABD00035951-D
Active

ABB ACS880-01 series, LV AC industrial wall-mounted single drive, 3ABD00035951-D, 75 kW normal-use, 145 A, IP21, Frame Size R6.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3ABD00035951-D — Power & Output
ParameterValue
Output power, normal duty75 kW
Output current, normal duty145 A
Output power, heavy duty55 kW
Output current, heavy duty105 A
Output power, light overload75 kW
Output current, light overload138 A
Efficiency class (IE)IE2
3ABD00035951-D — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00035951-D — Mechanical & Cooling
ParameterValue
Frame sizeR6
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeWall-mounted

Product details

The 3ABD00035951-D: This ABB ACS880-01-145A-3 is an LV AC industrial wall-mounted single drive, rated for 75 kW normal-use output at 145 A, with a heavy-duty capability of 55 kW at 105 A. It runs on a 380–415 V three-phase supply across 47.5–63 Hz. The IP21 enclosure and NEMA Type 1 rating suit it for clean indoor environments — no washdown, no dust.

Frame size and mounting

Frame size R6, wall-mounted. At 75 kW and IP21, expect a cabinet footprint that matches the R6 mechanical outline — plan your backplate layout around that envelope. The wall-mount design keeps the gland plate accessible for top or bottom cable entry.

Three duty ratings are listed: normal-use (Pn 75 kW, In 145 A), light-overload (PlD 75 kW, IlD 138 A), and heavy-duty (PhD 55 kW, IhD 105 A). For a constant-torque conveyor or pump running at nameplate, the normal-use figure governs. The light-overload column (138 A) covers applications with occasional short peaks — fan or centrifugal pump starting profiles.

Frequently asked questions

What is the frame size of this drive?

Frame size R6.

What input voltage and frequency does it accept?

380–415 V three-phase, 47.5–63 Hz.

What are the normal-use and heavy-duty current ratings?

Normal-use output current is 145 A (75 kW); heavy-duty output current is 105 A (55 kW).

MPN