Skip to main content
ABB 3ABD00035978-D — AC Drive (VFD) 480V

ACS880-01-05A6-3+B056 2.2 kW Drive, 3ABD00035978-D, IP55

MPN3ABD00035978-D
Active

ABB ACS880-01 series, wall-mounted single drive, 3ABD00035978-D, 2.2 kW normal duty, 5.6 A output, 380...415 V 3-phase input, IP55, IE2 efficiency, frame size R1.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3ABD00035978-D — Power & Output
ParameterValue
Output power, normal duty2.2 kW
Output current, normal duty5.6 A
Output power, heavy duty1.5 kW
Output current, heavy duty4 A
Output power, light overload2.2 kW
Output current, light overload5.3 A
Efficiency class (IE)IE2
3ABD00035978-D — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00035978-D — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeType12
Degree of protection (IP)IP55
Mounting typeWall-mounted

Product details

What this drive delivers — and where the ratings matter

The ABB 3ABD00035978-D is an ACS880-01 wall-mounted single drive rated 2.2 kW normal-duty output at 5.6 A, with a heavy-duty ceiling of 1.5 kW at 4 A — the number to watch if you're driving a constant-torque load like a conveyor or positive-displacement pump. Light-overload use (variable-torque fans, centrifugal pumps) sees 2.2 kW at 5.3 A. Input is 380...415 V three-phase, 47.5...63 Hz, so it lands squarely on standard 400 V industrial mains across 50/60 Hz regions. The IP55 / NEMA Type 12 enclosure means it handles dust and hose-down in the same cabinet bay — no separate enclosure needed for washdown areas, though you still want the conduit entry sealed. IE2 efficiency is the baseline for this power class — adequate for most constant-torque applications, though newer premium-motor retrofits may push toward IE3 or IE4 on the motor side.

Lifecycle and sourcing — active line, quoted to order

Status is active per ABB's current lifecycle record, so this order code is still in normal production.

Frequently asked questions

What are the normal-duty and heavy-duty ratings for this drive?

Normal-duty output is 2.2 kW at 5.6 A; heavy-duty output is 1.5 kW at 4 A. Light-overload (variable-torque) rating matches the normal-duty power at 2.2 kW but draws 5.3 A.

What protection rating does the enclosure carry?

IP55 per IEC and NEMA Type 12. Suitable for dust-protected and hose-down environments; the wall-mount design allows direct panel or machine mounting without an additional cabinet in many washdown zones.

MPN