The ABB 3ABD00038141-D is an ACS880-01 wall-mounted drive rated for 1.5 kW normal-use output at 4 A, with a heavy-duty rating of 1.1 kW at 3.3 A. It runs on 380–415 V three-phase input, 47.5–63 Hz, and carries an IE2 efficiency class.
Duty ratings and real-world fit
The heavy-duty curve drops to 3.3 A at 1.1 kW — that's the figure to use for a 1.1 kW motor on a demanding cycle with short overload peaks. Light-overload use sits at 3.8 A, 1.5 kW, which matches the normal-use power but with a slightly lower current ceiling; if your motor draws 3.8 A continuous, the light-overload rating is the one that governs thermal headroom.
Wall-mounted, NEMA Type 1 enclosure with IP21 ingress protection — suitable for indoor, dry locations where drips or falling dust are the main concern. The R1 frame size keeps the gland plate area manageable for 4–6 mm² power cables. Ambient temperature derating applies above 40 °C; the drive's thermal design assumes free air circulation around the heatsink fins.