ABB 3ABD00038206-D — AC Drive (VFD) 480V

ABB 3ABD00038206-D ACS880 Drive, 75 kW, 145 A, Frame R6

MPN3ABD00038206-D
Active

ABB, ACS880 series, LV AC industrial wall-mounted single drive, 3ABD00038206-D, 75 kW / 145 A normal use, 55 kW / 105 A heavy duty, 380-415 V 3-phase, Frame R6, IP21, IE2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Power & Output

3ABD00038206-D — Power & Output
ParameterValue
Output power, normal duty75 kW
Output current, normal duty145 A
Output power, heavy duty55 kW
Output current, heavy duty105 A
Output power, light overload75 kW
Output current, light overload138 A
Efficiency class (IE)IE2

Input / Supply

3ABD00038206-D — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz

Mechanical & Cooling

3ABD00038206-D — Mechanical & Cooling
ParameterValue
Frame sizeR6
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeWall-mounted

Product details

The 3ABD00038206-D: Normal-use (Pn 75 kW, In 145 A) is the continuous rating for a standard variable-torque load like a fan or pump. Heavy-duty (PhD 55 kW, IhD 105 A) is the constant-torque rating for conveyors, extruders, or high-start-torque applications. Light-overload (PlD 75 kW, IlD 138 A) sits between the two — same power as normal but lower current, useful when the motor is oversized for the load. Frame R6 is the physical chassis size; verify backplate dimensions and mounting hole pattern against your panel layout before ordering.

IP21 and NEMA Type 1 means it is drip-proof and suitable for clean, indoor, non-condensing environments. Wall-mounted, so plan for adequate clearance above and below for airflow — the drive pulls cooling air from the bottom and exhausts at the top.

Rated IE2 efficiency, which meets the minimum for most industrial installations in regions where IE2 is the baseline for variable-speed drives. WEEE Category 4 (Large Equipment) applies for end-of-life take-back compliance.

Frequently asked questions

What is the frame size of this drive?

Frame R6. This determines the physical mounting footprint and backplate dimensions for panel layout.

What are the power and current ratings for normal vs. heavy-duty use?

Normal use: 75 kW, 145 A. Heavy-duty use: 55 kW, 105 A. Light-overload: 75 kW, 138 A.

What enclosure protection does it have?

IP21 and NEMA Type 1, suitable for clean indoor environments. Not rated for outdoor or washdown locations.

MPN