Skip to main content
ABB 3ABD00039334-D — AC Drive (VFD) 480V

ABB 3ABD00039334-D ACS880 Drive Module, 450 kW, 820 A, Frame

MPN3ABD00039334-D
Active

ABB ACS880-04 series, LV AC industrial single drive module, 450 kW normal-use output, 820 A, frame size R10, IP20, IE2, 380-415 V three-phase input.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Power & Output

3ABD00039334-D — Power & Output
ParameterValue
Output power, normal duty450 kW
Output current, normal duty820 A
Output power, heavy duty355 kW
Output current, heavy duty625 A
Output power, light overload450 kW
Output current, light overload810 A
Efficiency class (IE)IE2

Input / Supply

3ABD00039334-D — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz

Mechanical & Cooling

3ABD00039334-D — Mechanical & Cooling
ParameterValue
Frame sizeR10
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule

Product details

The ABB 3ABD00039334-D is an ACS880-04 series LV AC industrial single drive module rated for 450 kW normal-use output at 820 A, with a heavy-duty rating of 355 kW at 625 A for cyclic or high-torque loads. The 380-415 V three-phase input matches standard European industrial mains, and the 47.5 to 63 Hz frequency range covers 50 Hz and 60 Hz grids without derating. Frame size R10 tells the cabinet engineer the mounting footprint and bus-bar layout needed before the drive arrives on site.

Efficiency and enclosure for panel integration

Rated IE2 efficiency level, so it meets the minimum regulatory threshold for industrial drives in most jurisdictions without requiring premium-efficiency hardware. The open-type NEMA classification (no additional enclosure) confirms this; plan for gland plates and filtered airflow in the panel design.

Frequently asked questions

What is the frame size and what does it affect?

Frame size R10 determines the physical mounting dimensions, bus-bar spacing, and cabinet cutout requirements. It is the largest common frame in the ACS880-04 modular drive family, sized for the 820 A output current.

What input voltage and frequency does this drive accept?

Three-phase input from 380 to 415 V AC, 47.5 to 63 Hz, covering both 50 Hz and 60 Hz industrial supplies without adjustment.

What is the difference between the normal-use and heavy-duty ratings?

Normal-use rating is 450 kW / 820 A for continuous constant-torque loads like pumps and fans. Heavy-duty rating is 355 kW / 625 A for applications with higher peak torque demands or cyclic overload profiles, such as conveyors or crushers.

MPN
3ABD00039334-D