The ABB 3ABD00039342-D is an ACS880-04 LV AC industrial single drive module rated for 450 kW normal-use output at 820 A, with a heavy-duty rating of 355 kW at 625 A. It accepts 380-415 V three-phase input across 47.5-63 Hz and carries IE2 efficiency. The IP20 open-type enclosure and Frame Size R10 define the physical footprint for panel layout.
ABB 3ABD00039342-D ACS880-04 Drive Module, 450 kW, 820 A
MPN3ABD00039342-D
Active
ABB ACS880-04 LV AC industrial single drive module, 3-phase 380-415 V input, 450 kW / 820 A normal use output, IP20, Frame Size R10.
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Specifications
Power & Output
| Parameter | Value |
|---|---|
| Output power, normal duty | 450 kW |
| Output current, normal duty | 820 A |
| Output power, heavy duty | 355 kW |
| Output current, heavy duty | 625 A |
| Output power, light overload | 450 kW |
| Output current, light overload | 810 A |
| Efficiency class (IE) | IE2 |
Input / Supply
| Parameter | Value |
|---|---|
| Input voltage range | 380 ... 415 V |
| Number of phases | 3-phase |
| Frequency | 47.5 ... 63 Hz |
Mechanical & Cooling
| Parameter | Value |
|---|---|
| Frame size | R10 |
| NEMA enclosure type | Open Type |
| Degree of protection (IP) | IP20 |
| Mounting type | Module |
Product details
Frequently asked questions
What are the key output ratings for this drive module?
Normal-use output is 450 kW at 820 A; heavy-duty use is 355 kW at 625 A; light-overload use is 450 kW at 810 A.
What is the frame size and enclosure type?
The frame size is R10, and the enclosure is IP20 open type.
What input voltage and frequency does it accept?
It accepts 380-415 V three-phase input at 47.5-63 Hz.
MPN
3ABD00039342-D