Specifications

Power & Output

3ABD00039398-D — Power & Output
ParameterValue
Output power, normal duty315 kW
Output current, normal duty585 A
Output power, heavy duty250 kW
Output current, heavy duty429 A
Output power, light overload315 kW
Output current, light overload575 A
Efficiency class (IE)IE2

Input / Supply

3ABD00039398-D — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz

Mechanical & Cooling

3ABD00039398-D — Mechanical & Cooling
ParameterValue
Frame sizeR11
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule

Product details

The ABB 3ABD00039398-D is an ACS880-04 low-voltage AC industrial single drive module rated for 315 kW normal use (585 A) and 250 kW heavy-duty use (429 A) on a 380-415 V three-phase supply. Frame size R11, IP20 open-type enclosure. It handles 47.5 to 63 Hz line frequency and carries IE2 efficiency classification.

The heavy-duty output current (429 A at 250 kW) is the figure that governs motor starting and overload cycles — use it for pump, fan, or conveyor applications that demand sustained torque at low speed. The normal-use rating (585 A at 315 kW) applies to variable-torque loads like centrifugal fans or pumps where peak current stays within the drive's continuous capability. Light-overload use (575 A, 315 kW) sits close to the normal-use curve and suits constant-torque applications with infrequent overloads.

Module mounting, IP20 open type. Frame R11 determines the physical footprint and bus-bar layout — verify cabinet depth and gland-plate clearance against the ACS880-04 installation manual before panel layout. The drive accepts 380-415 V three-phase input; line reactors or input chokes may be required for compliance with harmonic limits, depending on the supply impedance.

Frequently asked questions

What frame size is 3ABD00039398-D?

Frame size R11.

What line frequency range does this drive accept?

47.5 to 63 Hz.

What are the normal-use and heavy-duty output ratings?

Normal use: 315 kW / 585 A. Heavy-duty use: 250 kW / 429 A.

MPN