Skip to main content
ABB 3ABD00039406-D — AC Drive (VFD) 480V

ABB 3ABD00039406-D ACS880-04 Drive Module, 315 kW, 585 A

MPN3ABD00039406-D
Active

ABB ACS880-04 LV AC industrial single drive module, Frame R11, 380-415 V 3-phase, 315 kW / 585 A normal use, 250 kW / 429 A heavy duty, IP20, IE2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Power & Output

3ABD00039406-D — Power & Output
ParameterValue
Output power, normal duty315 kW
Output current, normal duty585 A
Output power, heavy duty250 kW
Output current, heavy duty429 A
Output power, light overload315 kW
Output current, light overload575 A
Efficiency class (IE)IE2

Input / Supply

3ABD00039406-D — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz

Mechanical & Cooling

3ABD00039406-D — Mechanical & Cooling
ParameterValue
Frame sizeR11
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule

Product details

It delivers 315 kW output power at 585 A in normal use, with a heavy-duty rating of 250 kW at 429 A for tougher loads. Input is 380-415 V three-phase, 47.5-63 Hz, and the unit carries an IE2 efficiency level. Frame size is R11, enclosure is IP20 Open Type — it's meant for a panel, not standalone.

Sizing and duty

The normal-use rating (315 kW, 585 A) covers continuous motor operation at full load. Heavy-duty use (250 kW, 429 A) applies when the drive sees overload cycles — conveyors, crushers, pumps with high starting torque. Light-overload use (315 kW, 575 A) sits close to normal but with a slightly different current curve. Pick the duty class that matches your load profile; the heavy-duty number is the one that keeps the drive alive on a tough line.

Frame R11 is a cabinet-mount module, IP20 rated — no external weatherproofing. Open Type NEMA enclosure means it needs a clean, dry panel environment. Three-phase input at 380-415 V, frequency range 47.5-63 Hz covers 50/60 Hz grids. The 585 A normal-use current dictates busbar and cable sizing; plan for adequate copper cross-section and ventilation around the heat sink.

Frequently asked questions

What is the frame size of this drive module?

Frame size is R11.

What are the key power ratings for normal and heavy-duty use?

Normal use: 315 kW at 585 A. Heavy-duty use: 250 kW at 429 A. Light-overload use: 315 kW at 575 A.

MPN
3ABD00039406-D