The 3ABD00046987-D: Normal-use output (45 kW, 87 A) covers constant-torque loads like conveyors or pumps at full rated current. Heavy-duty use (37 kW, 72 A) applies for higher starting torque or cyclic overloads — the drive delivers 72 A continuous in that mode, which is the figure to size against for a crusher or extruder duty cycle. Light-overload use (45 kW, 83 A) sits between the two, for applications with moderate overload profiles.
Wall-mounted, IP21 / NEMA Type 1 — suitable for indoor, clean environments.