Skip to main content
ABB 3ABD00057677-D — AC Drive (VFD) 480V

ABB 3ABD00057677-D ACS880-01 Drive, 55 kW, 105 A, R6

MPN3ABD00057677-D
Active

ABB ACS880-01 industrial wall-mounted single drive, 3ABD00057677-D, 55 kW normal-use output, 105 A, R6 frame size, IP21, NEMA 1, IE2 efficiency.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3ABD00057677-D — Power & Output
ParameterValue
Output power, normal duty55 kW
Output current, normal duty105 A
Output power, heavy duty45 kW
Output current, heavy duty87 A
Output power, light overload55 kW
Output current, light overload100 A
Efficiency class (IE)IE2
3ABD00057677-D — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00057677-D — Mechanical & Cooling
ParameterValue
Frame sizeR6
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeWall-mounted

Product details

The 3ABD00057677-D: Wall-mounted with an IP21 / NEMA Type 1 enclosure — that's drip-proof, not washdown. Fine for a dry electrical room or a climate-controlled MCC building, but don't hang it under a steam vent or a wash hose in a pulp mill wet-end. The R6 frame has generous gland-plate space for incoming power and motor cables up to 185 mm², and the DC bus terminals are accessible for adding a braking chopper or a common DC link if you're tying multiple drives together on a sectional drive line.

The dual current ratings — 105 A normal-use (light overload) and 87 A heavy-duty — are the key selection numbers. Normal-use covers centrifugal pumps, fans, and conveyors where the load rarely exceeds nameplate. Heavy-duty at 87 A handles constant-torque loads like extruders, mixers, or a paper machine helper drive that needs 150 % torque for 60 seconds to break away a stalled roll. If your application is a variable-torque fan at 55 kW, the 105 A rating is comfortable. If it's a positive-displacement pump or a winder that cycles through tension peaks, size against the 87 A heavy-duty curve.

Frequently asked questions

What frame size is 3ABD00057677-D?

The drive uses an R6 frame size, which is a wall-mounted enclosure for the 55 kW power class.

What is the input voltage and frequency range?

Input voltage is 380-415 V three-phase, 47.5-63 Hz, covering 50/60 Hz grids globally.

What are the normal-use vs heavy-duty current ratings?

Normal-use (light overload) output is 105 A at 55 kW. Heavy-duty output is 87 A at 45 kW. Light-overload use is rated 100 A at 55 kW.

What enclosure protection does this drive have?

IP21 per IEC and NEMA Type 1. Suitable for indoor, dry locations; not rated for washdown or outdoor installation.

MPN