ABB 3ABD00058039-D — AC Drive (VFD) 480V

ABB 3ABD00058039-D ACS880-01 Drive, 250 kW, 430 A, R9

MPN3ABD00058039-D
Active

ABB ACS880-01 wall-mounted single drive, 250 kW / 430 A normal duty, 380-415 V 3-phase, IP20 open type, frame R9.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Power & Output

3ABD00058039-D — Power & Output
ParameterValue
Output power, normal duty250 kW
Output current, normal duty430 A
Output power, heavy duty200 kW
Output current, heavy duty363 A
Output power, light overload200 kW
Output current, light overload400 A

Input / Supply

3ABD00058039-D — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz

Mechanical & Cooling

3ABD00058039-D — Mechanical & Cooling
ParameterValue
Frame sizeR9
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeWall-mounted

Product details

The 3ABD00058039-D is an ABB ACS880-01 wall-mounted single drive rated for 250 kW normal-duty output at 430 A, with heavy-duty capability at 200 kW / 363 A. It runs on 380-415 V three-phase input, 47.5-63 Hz, in an IP20 open-type enclosure, frame size R9.

Normal-duty (Pn 250 kW, In 430 A) covers constant-torque loads like conveyors and pumps at full nameplate. Light-overload (PlD 200 kW, IlD 400 A) splits the difference; it's the same power as heavy but with slightly higher current headroom, useful for variable-torque fans with occasional peak demand.

Wall-mounted, IP20 open type. That means it's for indoor, clean panel environments—not washdown or dust. Frame R9 is a substantial enclosure; plan for adequate lifting points and panel door clearance during installation.

Frequently asked questions

What is the frame size of this drive?

Frame size R9.

What input voltage and frequency does it accept?

380-415 V three-phase, 47.5-63 Hz.

MPN